LT30 series Grip type multi-axis operating handle
Caractéristiques du produit
Spring automatically resets, single-axis or dual-axis operation.
You can choose to operate in the cross direction or in any direction.
The angle detection device is a potentiometer or Hall sensor, which has a long service life.
Configurable high current micro switch (10A @ 30Vdc).
Various output formats are available.
Can be configured with a variety of models
Domaine d'application
This series of products are mainly used in aerial work trucks, rotary drilling rigs, aerial fire trucks, cranes, shield machines and other electrical and electro-hydraulic control systems.
Informations techniques
Paramètres électriques
Potentiometer type
Tension d'alimentation | <36Vdc |
Total resistance value | 5KΩ, 10KΩ |
Center dead zone angle | ± 3 ° |
Maximum power | 0.2W |
Type de salle
Power supply voltag | e5 ± 0.5Vdc |
Limite de la surtension admissible | 20Vdc |
Tension admissible de la limite inverse | -10Vdc |
Erreur linéaire de la tension de sortie | <± 0.2V |
With conversion circuit
Tension d'alimentation | 18 ~ 36Vdc (U 21 ~ U 24) |
Power consumption current | <20mA |
Maximum output current | 10mA (at standard voltage output) |
Micro-interrupteur
Load capacity | 10A @ 30Vdc (resistive load) |
Durée de vie | > 30 million times or more (mechanical) |
> 200,000 times (electrical) | |
Insulation resistance | 100MΩ or more (500Vdc insulation resistance meter) |
Starting angle | ± 3 ° ~ ± 5 ° |
Paramètres mécaniques
Angle de basculement | ± 25 ° |
Mode de fonctionnement | Retour automatique par ressort |
Force de démarrage | 5N |
Force maximale de fonctionnement | 30N |
Force de limitation | >300N |
Durée de vie | >2 million times (potentiometer type) |
5> million times (Hall type) | |
Poids | 460g (no upper end) |
Paramètres environnementaux
Température de travail | -30 ℃ ~ + 70 ℃ |
Température de stockage | -40 ℃ ~ + 85 ℃ |
Niveau de protection | IP65 (au-dessus du panneau d'installation) |
Sélection des produits
LT30 series
Mode opératoire
1A | Single-axis front-back operation |
2AP | Dual axis cross operation direction |
2AC | any operation direction of two axes |
Micro-interrupteur
MS00 | without micro switch |
MS22 | with 10A front and back position micro switch |
MS23 | with 10A neutral position normally closed and front and back position micro switch |
Signal de sortie
Potentiometer type | (supply voltage <36VDC)
P051 | 5KΩ center tapped potentiometer |
P101 | 10kΩ center tapped potentiometer |
Hall type (supply voltage 5VDC)
H51 | 0,5 ~ 2,5 ~ 4,5Vdc tension de sortie |
H52 | 0 ~ 2.5 ~ 5Vdc voltage output |
H53 | 1.25V ~ 2.5V ~ 3.75Vdc voltage output |
With conversion circuit
U21 | power supply voltage 18 ~ 36Vdc, -10V ~ 0V ~ + 10V voltage output |
U22 | power supply voltage 18 ~ 36Vdc, + 10V ~ 0V ~ + 10V voltage output |
U23 | power supply voltage 18 ~ 36Vdc, -5V ~ 0V ~ + 5V voltage output |
U24 | power supply voltage 18 ~ 36Vdc, + 5V ~ 0V ~ + 5V voltage output |
I21 | power supply voltage 9 ~ 36Vdc, two-wire system 4mA ~ 12mA ~ 20mA current output |
I22 | power supply voltage 9 ~ 36Vdc, two-wire system 20mA ~ 4mA ~ 20mA current output |
I41 | power supply voltage 9 ~ 36Vdc, four-wire 4mA ~ 12mA ~ 20mA current output |
I42 | power supply voltage 9 ~ 36Vdc, four-wire 20mA ~ 4mA ~ 20mA current output |
NA | no analog signal output |
Extrémité supérieure de la poignée
BG | upper end of BG type handle, top palm operation |
HA | upper end of HA type handle, no button on top |
HAS | the upper end of the HAS-type handle with buttons on the top |
HD | upper end of HD handle, no button on top |
HDS | upper end of HDS type handle, with button on top |
HDR | upper end of HDR type handle, seesaw on top |
KG DR | with safety switch and rocker button |
KG DN | with safety switch, without rocker button |
Caractère extraverti
C | terminal block |
A | Connecteur AMP |