TJ140 series
Thumb-type dual-axis operating handle
Produktmerkmale
● Thumb operation
● Spring return
● Dual-axis operation at any angle in any direction.
● Hall contactless detection
● A variety of handles can be selected
● Switching output optional
Anmeldung
This series of products is mainly used in various operation handles, operation panels, and satellite remote control.
Technical Information
Electrical parameters
Power supply current | 5 ± 0,5 Vdc |
Electrical angle | ± 25 ° |
Maximum supply current | 10mA |
Median output voltage | 2.5 ± 0.1V |
Linearer Fehler der Ausgangsspannung | < ± 0.2V |
Begrenzung der zulässigen Überspannung | 30Vdc |
Umgekehrter Grenzwert der zulässigen Spannung | -15Vdc |
Mechanical parameters
Rocking angle | ± 25 ° |
Arbeitsweise | Automatic spring return |
Startkraft | about 2N |
Operating force | about 5N |
Begrenzende Kraft | about 100N |
Service life | > 1 million times |
Gewicht | about 18g |
Environmental parameters
Arbeitstemperatur | -30 ℃ ~ + 70 ℃ |
Lagertemperatur | -40 ℃ ~ + 85 ℃ |
Schutzgrad | IP68 (above the installation panel) |
Product Configuration
TJ140 series
Operation method
1A | Single axis operation in front and back direction |
2AC | any operation direction of dual axes (with guide groove |
Ausgangssignal
2H51 | Dua-Hall type, 0.5 ~ 2.5 ~ 4.5Vand 4.5~2.5~0.5V voltage output |
SW | switch output |